Application of the Fanger methodology in the Mossone de la Huacachina hotel in Ica 2021

Authors

DOI:

https://doi.org/10.47796/ra.2022i21.631

Keywords:

Fanger method, percentage of dissatisfied people (PPD), estimated average vote (PMV)

Abstract

The limited knowledge we have about the Fanger methodology applied in the hotel industry, results in bad practices when proposing designs, not shortening with the place of study, obtaining suffocating or very cold environments. It is for this same need that the aforementioned methodology is used, in order to incorporate said work strategy in an extreme climate within the Peruvian territory, choosing Ica as the place of study and the Hotel Mossone as part of the application of the method. Fanger, due to its history, its typical hotel architecture, the great tourist traffic it houses and the histo rical heritage it represents. Focusing only on finding the percentage of dissatisfied people (PPD) and the estimated mean vote (PMV) with respect to thermal comfort in social and private environments. Reaching the conclusion that on the dates from 05/04/21 to 05/30/21 a dominant percentage perceives a slightly cool environment and 72% of people dissatisfied according to the (PPD), so it could be assumed that, on the dates of May, the Hotel Mossone lacks thermal comfort.

Downloads

Download data is not yet available.

References

Auliciems, A., y Szokolay, S. V. (2007). Thermal Comfort. https://opencourses.emu.edu.tr/pluginfile.php/4408/course/section/786/MENG443%20PPT1B.pdf.

Dear, R. (2004). Thermal comfort in practice. Indoor Air, 14(s7), 32-39. https://doi.org/10.1111/j.1600-0668.2004.00270.x.

Godoy, A. (2012). El confort térmico adaptativo. Aplicación en la edificación en España. https://upcommons.upc.edu/handle/2099.1/18763.

Gonzales, C. M. A. (2014). Laguna de la Huacachina Historia, Morfología y Arquitectura. PUCP. https://issuu.com/magc04/docs/huacachina.

MINCETUR, V., DGIETA. (2020). Reporte Regional de Turismo - Ica 2020. https://www.gob.pe/institucion/mincetur/informes-publicaciones/1212825-reportes-de-turismo-reporte-regional-de-turismo-ica-2020.

Negro, S. (2017). La laguna Huacachina en Ica, una oportunidad de gestión al borde del abismo. https://cicopperu.com/2017/02/03/la-laguna-de-huacachina-en-ica-una-oportunidad-de-gestion-al-borde-del-abismo/.

Nikolopoulou, M. (2011). Outdoor thermal comfort.

Plaza, E. L. (2016). Composición arquitectónica, materialidad y confort térmico en clima cálido húmedo [Tesis de maestría]. Repositorio Institucional Universidad Piloto de Colombia Re-Pilo. https://core.ac.uk/display/226163915.

Sahid, N., Rahim, R., Hamzah, B., & Mulyadi, R. (2019). Analysis of Indoor Thermal Comfort of Room Space in the International Standard Hotel Building. Advances in Social Sciences Research Journal, 6. https://doi.org/10.14738/assrj.62.6195.

Vilella, C. E. (1983). NTP 74: Confort térmico - Método de Fanger para su evaluación. https://www.insst.es/documents/94886/326853/ntp_074.pdf/1a5d4655-f44d-4118-9516-281a452e820d.

Published

2022-07-23

Issue

Section

Articles

How to Cite

Cutipa Montoya, F. E., Chura Chura, A. R., & Gudiel Rodriguez, E. R. (2022). Application of the Fanger methodology in the Mossone de la Huacachina hotel in Ica 2021. Arquitek, 21. https://doi.org/10.47796/ra.2022i21.631